Changing EBSP200 from F to CUpdated 7 months ago

The process for changing an EBSP200 PID from Farenheight or Celsius to the opposite is as follows:

  1. Press SET and < at the same time, PASS will appear
  2. Enter 0101 and press SET, INPT will appear
  3. Press SET until you see UNIT
  4. Pressing the UP/F2 or DOWN/F1 keys, you can change from F to C or C to F depending on your desired unit.
  5. Press SET again to save
  6. Then press SET and < to return the Present and Set value display.

Panels assembled will typically ship setup for Farenheight but PIDs shipped as parts will ship in Celsius.